Where to buy | Partner Center | eShop

8-Outlet eco PDU


PE6208AV

Ideal for Pro-A/V applications, the ATEN NRGence™ PE6208AV eco PDUs are intelligent, 1U rack PDUs that contain 8 AC outlets available in an IEC socket configuration. The unique design with detachable front panel is convenient and mounts with different Pro-A/V equipment in 19” racks with different depths. In addition to remotely controlling individual outlets over the LAN, the front panel pushbuttons offer an extra option to control the outlets locally, allowing the flexibility to easily shutdown Pro-A/V equipment on the spot or from a remote location – for reduced power consumption. The outlets feature a sequential power-ON function that ensures Pro-A/V systems are powered on safely. Furthermore, compatibility with the ATEN Control System and Control4 libraries allow the PE6208AV to integrate with any Pro-A/V equipment for full control of all devices without complex programming.

The PE6208AV are optimal energy solutions for data centers as well. With the combination of ATEN eco PDUs and eco Sensors Energy Management software, a data center will be equipped with real-time monitoring, measurement, and analysis of energy consumption – with reports of power usage, PUE, RCI, and RTI to meet the ISO 50001 requirements. These indices reflect the data center’s energy usage and offer energy saving suggestions for optimizing energy use and reducing costs.

ROHS Weee

Package Contents

  • 1x PE6208AV Power Distribution Unit
  • 1x Power Cord
  • 1x RJ-45 Cable
  • 1x Cable Ties
  • 1x Footpad Set
  • 1x Mounting Kit
  • 1x User Instructions
  • Connections
  • Detachable front panel fits 19” racks with different depths
  • Built-in 10/100 Mbit Ethernet Interface
  • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet
  • 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS
  • Browser access via IE, Firefox, Chrome, Safari, and more
  • Easy integration with ATEN Control System and Control4 libraries
  • Supports RS-232 port and power outlet control (on/off) by outlet group



  • Metering
  • 1% Metering Accuracy – supports bank-level power metering
  • Environment Monitoring – supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring



  • Outlet Switch Control
  • Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • Multiple Power Control Methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-On Sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety
  • Proactive Overload Protection (POP) – automatically powers off the last outlet that caused the current overload to protect high-end pro-A/V equipment and servers



  • eco Sensors Energy Management Software*
  • Automatic discovery of all ATEN PDUs within the same intranet
  • Remote real-time power measurement and monitoring of PDUs
  • Real-time environment monitoring via sensors
  • Plotting and monitoring of all ATEN PDU devices
  • Exceed threshold alerts through real-time monitoring, SMTP, and System logs
  • Power analysis reports

    * eco Sensors is designed to work with NRGence™ eco PDUs and is bundled with all PE Series models.


FunctionPE6208AVAPE6208AVBPE6208AVGPE6208AVX
Electrical
Nominal Input Voltage100 – 120 VAC100 – 240 VAC100 – 240 VAC100 – 240 VAC
Maximum Input Current20A(Max), 16A(UL de-rated)16A(Max)(UL de-rated)
16A(Max)16A(Max)
Input Frequency50-60 Hz50-60 Hz50-60 Hz50-60 Hz
Input ConnectionA/J:NEMA L5-20P+IEC C19
A2/J2: NEMA 5-20P+IEC C19
NEMA 6-20P
IEC 60320 C20
Terminal Block
Input Power2400VA(Max),1920VA(UL de-rated)4600VA(Max),3680VA(UL de-rated)3680 VA(Max)3680 VA(Max)
Outlet TypeTotal : 8 x NEMA 5-20RTotal: 8 x IEC320 C13
Total: 8 x IEC320 C13
Total: 8 x Terminal Block
Nominal Output Voltage100-120 VAC100 – 240 VAC100 – 240 VAC100 – 240 VAC
Maximum Output Current (Outlet)NEMA 5-20R : 20A (Max) 16A (UL de-rated)C13: 15A(Max) 12A(UL de-rated)C13: 10ATerminal Block: 16A
Maximum Output Current (Bank)20A (Max) 16A (UL de-rated)20A (Max) 16A (UL de-rated)16A(Max)16A(Max)
Maximum Output Current (Total)20A (Max) 16A (UL de-rated)20A (Max) 16A (UL de-rated)16A(Max)16A(Max)
MeteringPer Bank level Current, Voltage, VA , PF and KWh MonitoringPer Bank level Current, Voltage, VA , PF and KWh MonitoringBank Level Current, Voltage, VA , PF and kWh MonitoringPer Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet SwitchingYesYesYesYes
Environment Sensor Ports2222
Metering AccuracyVoltage range: 100VAC ~ 250VAC +/-1%
Power range: 100W ~ 5000W +/- 2%
Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage range: 100VAC ~ 250VAC +/-1%
Power range: 100W ~ 5000W +/- 2%
Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Voltage range: 100VAC ~ 250VAC +/-1%
Power range: 100W ~ 5000W +/- 2%
Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Communication
10/100 Mbps1 x RJ-451 x RJ-451 x RJ-451 x RJ-45
RS-2321 x DB-9
1 x DB-9
1 x DB-91 x DB-9
Switches
PowerYesYesYesYes
Physical Properties
Dimensions (L x W x H)43.24 x 26.72 x 4.40 cm
(17.02 x 10.52 x 1.73 in.)
43.24 x 26.72 x 4.40 cm
(17.02 x 10.52 x 1.73 in.)
43.24 x 26.72 x 4.40 cm
(17.02 x 10.52 x 1.73 in.)
43.24 x 26.72 x 4.40 cm
(17.02 x 10.52 x 1.73 in.)
Weight3.76 kg ( 8.28 lb )3.76 kg ( 8.28 lb )3.76 kg ( 8.28 lb )3.76 kg ( 8.28 lb )
Power Cord Length3 m3 m3 mNA
Environmental
Temperature (Operating / Storage)0 – 50℃ / -20 – 60℃0 – 50℃ / -20 – 60℃0–40°C / -20–60°C0 – 50℃ / -20 – 60℃
Humidity (Operating & Storage)0–80% RH, Non-Condensing0–80% RH, Non-Condensing0–80% RH, Non-Condensing0–80% RH, Non-Condensing
Compliance
EMC VerificationFCC, J55022FCC Others by RequestCE-EMC, FCC, J55022 Others by RequestCE-EMC, FCC,
Safety VerificationPSEOthers by RequestCE-LVD, PSE, Others by RequestCE-LVD
NoteFor some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.



DescriptionVer.Release DateFile Name
Firmware Upgradev1.9.184 pe8_v1.9.184.zip
Firmware Upgradev1.9.183 pe8_v1.9.183.zip
Firmware Upgradev1.2.113 pe6208av_v1.2.113.zip
Firmware Upgradev1.9.181 PE8_v1.9.181.zip
Firmware Upgradev1.8.178 PE8_v1.8.178.zip
Firmware Upgradev1.8.174 PE8_1.8.174.zip
Firmware Upgradev1.7.167 pe6108_6208_v1.7.167.zip
Firmware Upgradev1.6.159 pe6108_6208_v1.6.159.zip
Firmware Upgradev1.5.148 pe6108_6208_v1.5.148.zip
Firmware Upgradev1.1.133 pe6108_6208_v1.1.133.zip
Firmware Upgradev1.1.118 pe6108_6208_v1.1.118.zip
Firmware Upgradev1.1.109 pe6108_pe6208_v1.1.109.bin
Firmware Upgradev1.0.063 PE8_v1.0.063.bin
ОSDescriptionVer.Release DateFile Name
MIB Filev1.1.115 PE_MIB_File_v1.1.115.zip
PE MIB Filev1.1.112 PE8_MIB_File_v1.1.112.tar
PE MIB Filev1.1.109 PE8_MIB_File_v1.1.109.tar
IP Installerv1.4.132 IPInstaller-ALTUSEN_v1.4.132.zip
LinuxPMonitorv1.1 PowerMonitor_v1.1.zip
WindowsPMonitorv1.0.081 PMonitorSrv_v1.0.081.zip
PE MIB Filev1.0.063 PE8_MIB_File_v1.0.063.zip