Händler | Partner Portal | eShop

Release Note

Welcome to CC2000 Control Center Over the NET
Notice:
1. Before updating, please back up system configuration to avoid any potential data loss from unforeseen issues arising during the update.
2. Before downloading the software, be sure to read the following information carefully.
This latest version is cumulative and includes the corrections contained in all previous revisions. There is no need to install previous version if you are installing this one.
Version History
VersionDescriptionNote
v2.7.2611. Supports OTP(One Time Password)
2. Supports MAC OS as a client
3. Improve the performance of Auto Discovery
4. Improves the performance of VMware management
5. Improve the compatibility of JAVA version and browser
6. Improves the performance of Disclaimer
1. Please upgrade from V2.6.254
2. The CC2000 supports OTP function that is compatible with Changing Tech's MOTP product
3. Before attempting to add devices into CC2000 system, strongly recommend the latest firmware level for devices
v2.6.2541. Supported PE series PDU via SNMP device setting
2. Supported Disclaimer function
3. Supported password strength checking function
4. Added PDU power control confirmation and related settings
5. Improved CC server redundancy
6. Improved some Linux command for CC2000 installer to support most popular Linux (tested at Fedora 20, Ubuntu 13.10, Debian 7.4, CentOS 6.5 and OpenSUSE 13.1)
7. Improved certificate related process to support JRE 8
8. Improved CC viewer
9. Improved multi-server communication
10. Improved SPM Single Sign On (SSO) related pages for better browser compatibility
11. Fixed some bug regarding to UI of report functions
12. Fixed some bugs that related with CC Security application (ActiveX problem in Windows 7, Java Applet for Chrome)
1. Please upgrade from V2.5.241
2. Before attempting to add devices into CC2000 system, strongly recommend the latest firmware level for devices.
v2.5.2411.Added new Aten devices support (CN8600, SN0148)
2.Added iDRAC 6 standard rack server (monolithic) support
3.Added HP iLO3 support
4.Added VMware 5.x (vCenter 5.x, ESX server 5.x) support
5.Added access/asset report function
6.Added Unit Status Dashboard function in Port Access
7.Improved port access page loading speed
8.Improved notification email with detail description
9.Added new feature of database replication
10.Added Third party server auto-discovery function
11.Supported PuTTY as telnet and SSH client
12.Added unread message display in orange bar
1. Please upgrade from V2.0.193 or later
2. Due to database changed, this version of CC2000 is not compatible to communicate with any earlier CC2000 releases (V2.3.221 or earlier)
3. Before attempting to add devices into CC2000 system, strongly recommend the latest firmware level for devices.
cn8000: v2.3.222 or later
cn8600: v1.0.063 or later
cs1708i_1716: v1.3.124 or later
ip8000: v1.1.103 or later
kh1508i_1516i: v1.0.077 or later
kh1508ai_1516ai: v1.3.121 or later
kl1508ai_1516ai: v1.3.121 or later
kl9108_9116: v1.0.083 or later
kn1000: v1.1.101 or later
kn2108_2116: v1.1.103 or later
kn4140v:
kn4140v_4124v_2140v_2124v_kn4132_4116_2132_2116a_kn4132v_4116v_2132v_2116v: v1.7.166 or later
kn9008_9016: v1.3.127 or later
kn9108_9116: v1.2.113 or later
pn5212_5320: v1.5.145 or later
pn7212_7320: v1.5.145 or later
pn9108: v1.9.184 or later
sn0108_0116: v3.0.294 or later
sn0132_0148: v1.0.091 or later
sn3101: v1.3.125 or later
v2.3.2221. Improved CC Viewer to display Device Name and Port Name in CC viewer title bar
2. Added page control bar for some list type page (larger list page in “ Port Access ”, “ User Management ” and “ Device Management ”, etc.), integrated sorting, filtering and items per page in this control bar
3. Added power control in CC viewer tool bar if applicable (for CC2000 target device that is associated with some PDU outlet)
4. Added auto-push CC server list to device function (KN4140 firmware v1.7.162 and above) (With this function, KN4140´s “ Alternate CC Server Settings ” will show “ N/A ” due to the alternate CC server’s information will be sent to KN4140 automatically)
5. Added “ notification and message box ” function (system administrator could use this function to send notification to some or all CC2000 users)
6. Added “ Online message board ” function to provide online chatting support for all online users (the user who logged in to CC2000)
7. Added simple redundant support for target device (after CC server disconnected each other, the primary or substitute primary will try to connect this target device, if it is successful, user could access this target device via primary or substitute primary server)
8. Added Copy/paste access right function in “ User Management ” and “ Device Management ” page (by mouse right clicking at user/device node in user/device tree, the access right copy/past are allowed between compatible nodes only. e.g. user to user node, outlet to outlet node are allowed, but outlet to dongle node is not allowed)
9. Added “ Mapped IP ” field to virtualization wizard for adding VMware/Citrix (in case of CC server or VM server located behind a router)
10. Added some event and related logs as following,
• Transfer device settings
• Modify group member
• Server connected
11. Updated device configuration for IPv6 support (CS1716i, KN9016, KH1516Ai/KL1516Ai, KN1001)
12. Implemented simple SNMP support (agent, trap, trap receiver)
13. Implemented following new logs,
• Change server SNMP settings
• Modify SNMP trap options
• System notification issued
• System notification deleted
14. Improved VMware power operation menu to provide option for blocking power On/OFF operation if needed (by added following definition "/V/M/Powerflg"="0" to registry)
15. Improved CC viewer to support array mode better (switchable between the ports from different devices, target device only)
16. Improved some Java script for page refresh support in latest Firefox (V15.0.1, Firefox dropped some Java script support, it will cause CC2000 auto page refresh failure)
17. Improved Syslog TCP/SSL support (supported transfer device log to Syslog server via TCP/SSL channel)
18. Manually deleting unused node(s) function (all detachable node is allowed to be deleted manually. e.g. dongle, PN station are allowed to be deleted, but outlet is not allowed to be deleted)
19. Third party authentication with Kerberos server (Kerberos server works as standalone authentication server)
20. New device support (KN1116v, CN8000R2, KN1000R2, etc.)
21. Upgraded Apache Tomcat web server from 6.0.9 to 6.0.29 for security issue
22. Improved Syslog function (support for provide Syslog via TCP and Syslog via SSL)
23. Improved tasks including new time range option ("Since the last time task run": export new logs only for Export CC log/Device log, improved “ Run Now ” function as well)
24. Optimization for database replicate (exchange un-transferred logs only)
25. Improved PON port configuration page to support MAC address setting for “ Wake on LAN ” option
26. Improvement for port conflict detect (for resolving port conflict problem between CC2000 and VMware workstation)
27. Changed CC2000 username/password maximum length from 16 to 32 characters
28. Changed wording "Master/Slave" to "Primary/Secondary" (related web pages and related logs)
29. Fixed CC viewer related bugs (sometimes, array mode have no video displayed)
30. Fixed some bugs in multi-server and firewall/port mapping involved environment
1. Please upgrade from V2.0.193 or later
2. Due to database changed, this version of CC2000 is not compatible to communicate with any earlier CC2000 releases (V2.2.211 or earlier)
3. Before attempting to add devices into CC2000 system, they must be upgraded to the latest firmware level. You must use
cn8000: v2.0.192 or later
KN1000: v1.1.101 or later
cs1708i_1716: v1.2.112 or later
ip8000: v1.1.101 or later
kh1508i_1516i: v1.0.072 or later
kl9108_9116: v1.0.082 or later
kn2108_2116: v1.1.103 or later
kn4140v: v1.6.159 or later
kn4140v_4124v_2140v_2124v_kn4132_4116_2132_2116a_relay_v1.5.145.csf
(For KN4140v/KN4132 series, you must upgrade to relayversion v1.5.145 first for firmware v.1.5.xxx and previous)
kn9008_9016: v1.3.127 or later
kn9108_9116: v1.2.113 or later
pn9108: v1.9.184 or later
sn0108_0116: v2.1.201 or later
sn3101: v1.3.122 or later
v2.2.2121. Added KN1001 support (E00182/E00184, launch viewer, etc.)
2. Added KL1516Ai support (new device, same as KH1516Ai except model name)
3. Improved PN5/7 support
4. Improved KN1000 support (added schedule support)
5. Improved friendly Web UI
6. Added language option for email notification at SMTP setting page
7. Added VM (Virtual Media) read only access right for KN4140v series support
8. Added security filter (IP, MAC) for VM (Virtual Media) access control
9. Improved connectivity for VMRC
10 .Improved IPMI library
11. Improved KVM viewer to solve issues (e.g. array mode, VM, default setting, etc.)
12.Improved library for blade system support
13. Improved certificate related operation for JRE 7 compatibility
14. Improved log related function performance
15. Improved CC2000/device connection under NAT
16. Fixed some log related bugs
17. Fixed sorting bug in port access
18. Fixed RADIUS server connection test failure bug in multi-NIC environment
19. Fixed access right popup window problem for user access right settings
20. Fixed bug when set user expires date
21. Fixed VMRC download and execute problem in 64-bit Windows platform
22. Fixed SN session history search problem
23. Fixed error in port access for PON device from KN4140v series
24. Fixed Launch Java client problem in Linux
1. Please upgrade from V2.0.193 or later
2. Due to database changed, this version of CC2000 is not compatible to communicate with any earlier CC2000 releases (V2.2.211 or earlier)
3. Before attempting to add devices into CC2000 system, they must be upgraded to the latest firmware level. You must use
PN9108: V1.9.184 or later
PN0108: V2.0.195 or later
PN7320/PN7212/PN5320/PN5212: V1.2.111 or later
SN0108/0116: V2.0.199 or laterSN3101: V1.2.113 or later
KN4140v: V1.6.151 or later
KN2108/KN2116: V1.1.103 or later
KN9108/KN9116: V1.2.113 or later
KL9108/KL9116: V1.0.081 or later
KH1508i/KH1516i: V1.0.072 or later
CN8000R1: V1.6.151 or later
IP8000: V1.1.101 or later
CS1708i/CS1716i: V1.0.097 or later
KN9008/KN9016: V1.0.097 or later
KH1508Ai/KH1516Ai: V1.0.072 or later
KN1000: V1.0.066 or later
KN1001: V1.0.073 or later
KL1508Ai/KL1516Ai: V1.1.107 or later
V2.2.2111.Contains all fixes of previous releases (Patch 001-006 for V2.0.193)
2.Added server virtualization new platform support (Citrix XenServer)
3.Added new language support (French, Spanish, Portuguese)
4.Added power control options
5.Added APC PDU (AP79xx, AP89xx, AP86xx) support
6.Added Dell PowerEdge 1855/1955 blade system support
7.Added page number listing for easy management of logs
8.Improved device status display and control
9.Improved user roles and access right control
10.Improved data structure of “ database replicate ” task
11.Improved webpage loading speed
12.Integrated ATEN KVM and blade system
13.Expanded/improved target device (Service Processor supported)
1.Please upgrade from V2.0.193.
2.Before attempting to add devices into CC2000 system, they must be upgraded to the latest firmware level. You must use
PN9108: V1.9.184 or later
PN0108: V2.0.195 or later
PN7320/PN7212/PN5320/PN5212: V1.2.111 or later
SN0108/0116: V2.0.199 or later
SN3101: V1.2.113 or later
KN4140v: V1.6.151 or later
KN2108/KN2116: V1.1.103 or later
KN9108/KN9116: V1.2.113 or later
KL9108/KL9116: V1.0.081 or later
KH1508i/KH1516i: V1.0.072 or later
CN8000R1: V1.6.151 or later
IP8000: V1.1.101 or later
CS1708i/CS1716i: V1.0.097 or later
KN9008/KN9016: V1.0.097 or later
KH1508Ai/KH1516Ai: V1.0.072 or later
KN1000: V1.0.060
V2.0.1931. Supports blade server
2. Supports VMware virtual Infrastructure includes Center Servers, ESX Servers and Virtual Machines
3. Added new feature Panel DynaArray™
4. Supports Aten PDU with power association function
5. Added search function for log entries
6. Supports strong session management/integrates multi-session
7. Data export/import to remote server or local in real time or schedule
8. Supports data export with encryption
9. Supports OOBC, PAP, and CHAP authentication
10. Supports IPv6
11. Supports NTS
1. Please upgrade from V1.0.096.
2. Due to major changes have been made in this release, this version of CC2000 is not compatible with any earlier CC2000 releases, therefore, it could not communicate with earlier CC2000 releases (V1.0.096 or earlier)
3. Before attempting to add devices into CC2000 system, they must be upgraded to the latest firmware level. You must use
PN9108: V1.9.184 or later
PN0108: V2.0.195 or later
PN7320/PN7212/PN5320/PN5212: V1.0.081 or later
SN0108/0116: V2.0.199 or later
SN3101: V1.2.113 or later
KN4140v: V1.6.151 or later
KN2108/KN2116: V1.1.103 or later
KN9108/KN9116: V1.2.113 or later
KL9108/KL9116: V1.0.081 or later
KH1508i/KH1516i: V1.0.072 or later
CN8000R1: V1.6.151 or later
IP8000: V1.1.101 or later
CS1708i/CS1716i: V1.0.097 or later
KN9008/KN9016: V1.0.097 or later
KH1508Ai/KH1516Ai: V1.0.072 or later
V1.0.0961.Added a new feature to improve communication between a CC2000 and its supported devices.
2.Added support to allow configuration restores on a different master.
3.Added function to ensure that the masters and slaves are at the same firmware version.
1.Before attempting to add these devices into CC2000 system, they must be upgraded to the latest firmware level. You must use KN4140v_4124v_2140v_2124v_main_v1.1.108, KN4132_4116_2132_2116a_main_v1.1.108, KN2108_2116_main_v1.1.101, CN8000_v1.5.143, IP8000_v1.0.088, PN9108_fw_wb_v1.9.182, PN0108_v2.0.192 and SN0108_0116_v2.0.195 with this release.
2.The CC2000 Trial Version (CC2000-Demo-License) doesn't support software upgrading. In order to upgrade the software, you must purchase a license key and upgrade the License.
V1.0.0941. Added simple sorting for tree view pane (rule: sort device/folder by name, sort port by port number, sort group/aggregate device by device name port number, sort others by name)
2. Added checking device's F/W version support when adding a device. User must upgrade device's F/W to support CC2000 first.
3. Resolved filter issue by not allowing the "\"characters and non-ASCII characters to be used.
4. Improved real time status update method to avoid potential page display problems.
5. Added device trap event (missing in previous releases), resolved lost device trap problem
The CC2000 Trial Version (CC2000-Demo-License) doesn't support software upgrading. In order to upgrade the software, you must purchase a license key and upgrade the License.
V2.1.201Initial release.Also supports CC1000 USB License Key
V1.0.092Initial release.1.Before attempting to add these devices into CC2000 system, they must be upgraded to the latest firmware level.
You must use CCUSBKey_FW_v2.1.201, KN4140v_4124v_2140v_2124v_main_v1.1.108, KN4132_4116_2132_main_v1.1.108, KN2108_2116_main_v1.0.099, CN8000_v1.1.108, IP8000_v1.0.087, PN9108_fw_wb_v1.8.178, PN0108_v2.0.191 and SN0108_0116_v2.0.192 with this release.
2.The CC2000 Trial Version (CC2000-Demo-License) doesn't support software upgrading. In order to upgrade the software, you must purchase a license key and upgrade the License.