8-Outlet eco PDU - TAA Compliant


PE6108AV
  • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet
  • Supports RS-232 port and power outlet control (on/off) by outlet group
  • 1% Metering Accuracy – supports bank-level power metering
  • Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • TAA Compliant
MSRP: Quote Upon Request

Ideal for Pro AV applications, the PE6108AV eco PDU is intelligent 1U rack PDU that contains 8 AC outlets in an IEC socket configuration. The unique design with detachable front panel makes it convenient when mounting with different Pro AV equipment in 19” racks at varying depths. In addition to remotely controlling individual outlets over the LAN, the front panel pushbuttons offer an extra option to control the outlets locally, allowing the flexibility to easily shutdown Pro AV equipment on the spot or from a remote location – for reduced power consumption. The outlets feature a sequential power-on function that ensures Pro AV systems are powered on safely. Furthermore, compatibility with the ATEN Control System and Control4 libraries allows the PE6108AV to integrate with any Pro AV equipment for full control of all devices without complex programming.

The PE6108AV is an optimal energy solution for data centers as well. With the combination of ATEN eco PDUs and eco DC Energy & DCIM Management Web GUI, a data center will be equipped with real-time monitoring, measurement, and analysis of energy consumption – with reports of power usage and PUE to meet the ISO 50001 requirements. These indices reflect the data center’s energy usage and offer energy saving suggestions for optimizing energy use and reducing costs.

Package Contents

  • 1x PE6108AVA eco PDU
  • 1x Power Cord
  • 1x Mounting Kit
  • 1x RJ-45 Cable
  • 10x Cable Ties
  • 1x Footpad Set
  • 1x User Instructions
  • Connections
    • Detachable front panel fits 19” racks with different depths
    • Built-in 10/100 Mbit Ethernet Interface
    • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet
    • 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS
    • Browser access via IE, Firefox, Chrome, Safari, and more
    • Easy integration with ATEN Control System and Control4 libraries
    • Supports RS-232 port and power outlet control (on/off) by outlet group.



  • Metering
    • 1% Metering Accuracy – supports bank-level power metering
    • Environment Monitoring – supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring



  • Outlet Switch Control
    • Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
    • Multiple Power Control Methods – Wake on LAN, System After AC Back, Kill the Power
    • Power-On Sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety
    • Proactive Overload Protection (POP) :
      - automatically powers off outlets when current overloads to protect operating devices.
      - Priority Mode enables outlets to be powered off following the outlet shutdown order pre-defiend by the administrator via web browser
    • Auto Ping – the method pings a device at specified intervals, and if there is no response (request timed out), the PDU automatically powers cycles the outlet (off and then on)
    • Holiday Mode – when Holiday Mode is enabled, each outlet will be set to the selection chosen for it: POWER OFF or POWER ON



  • eco DC Energy & DCIM Management Web GUI*
    • Automatic discovery of all ATEN PDUs within the same intranet
    • Remote real-time power measurement and monitoring of PDUs
    • Real-time environment monitoring via sensors
    • Plotting and monitoring of all ATEN PDU devices
    • Exceed threshold alerts through real-time monitoring, SMTP, and System logs
    • Power analysis reports
      * eco DC is designed to work with ATEN eco PDUs and is bundled with all PE Series models.
Electrical
Nominal Input Voltage100 – 120 VAC
Maximum Input Current15A(Max), 12A(UL de-rated)
Input Frequency50-60 Hz
Input ConnectionFor A/J Plug:NEMA 5-15P
Input Power1800VA(Max),1440VA(UL de-rated)
Outlet TypeTotal : 8 x NEMA 5-15R
Nominal Output Voltage100-120 VAC
Maximum Output Current (Outlet)NEMA 5-15R : 15A (Max) 12A (UL de-rated)
Maximum Output Current (Bank)15A (Max) 12A (UL de-rated)
Maximum Output Current (Total)15A (Max) 12A (UL de-rated)
MeteringPer Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet SwitchingYes
Environment Sensor Ports2
Metering AccuracyVoltage range: 100VAC ~ 250VAC +/-1%
Power range: 100W ~ 5000W +/- 2%
Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Communication
10/100 Mbps1 x RJ-45
RS-2321 x DB-9
Switches
PowerYes
Environmental
Temperature (Operating / Storage)0 – 45℃ / -20 – 60℃
Humidity (Operating & Storage)0–80% RH, Non-Condensing
Physical Properties
Dimensions (L x W x H)43.24 x 26.73 x 4.40 cm
(17.02 x 10.52 x 1.73 in.)
Weight3.70 kg ( 8.15 lb )
Power Cord Length3 m
Compliance
EMC VerificationFCC, J55022
Safety VerificationPSE
NoteFor some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

We are here to help! Please visit ATEN eService for technical assistance.