30A/32A 30-Outlet 3-Phase Metered eco PDU
PG95330
- ARM Cortex-A8 processor for flexible control methods via LAN / COM / USB / environmental sensor ports and enhanced monitoring via LCD console
- Allows for connecting up to 64 PDU units with cascading
- Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
- 1 Gbps and 100 Mbps Ethernet ports
When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG95330 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG95330 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.
Hydraulic-Magnetic Circuit Breaker
With the built-in hydraulic-magnetic circuit breaker in place, electricity supply can be automatically switched off to protect connected devices from getting overloaded or damaged, while maintaining stable power distribution.
Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.
Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.
Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.
Dual LAN Ports for Scalable Network Setup
The PG95330 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.
Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.
Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.
Note: This feature is to be included in a future firmware release.
Contact Us
Get a quote for this product or get in touch with our sales experts
Networkable via WiFi
The PG95330 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.
Adjustable Power Cord for Flexible In-Rack Installation
The PG95330 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.
DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.
Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.
Applications
The PG series 3-Phase PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in a server room or data center.
Talk to Our Experts
If you prefer to have ATEN contact you, please complete the form and a representative will be in touch with you shortly
Package Contents
- 1 x Power Distribution Unit
- 1 x rack mount kit
- 1 x RJ-45 to DB-9 cable
- 1 x full-panel colored sticker
- 1 x user instructions
ATEN PG95330 3-Phase Metered eco PDU contains 6 x IEC 60320 C19 and 24 x IEC 60320 C13 outlets in a 0U rack enclosure. With an ARM Cortex-A8 processor, the PG95330 series delivers flexible control methods through its LAN / COM / USB / environment sensor ports as well as powers up all connected equipment in less than 10 seconds once plugged in. For cost-saving and space-efficient setup purposes, the PG PDUs can be cascaded to connect up to 64 PDU units. As a result, these PDUs accommodate the increasing demand for power to high-density IT devices in server rooms and data centers.
Other highlights include the circuit breaker preinstalled onto the PG95330 models that support 30A / 32A current flow, which automatically switches off electricity supply to protect devices from overload or damage. With five colors (yellow, red, purple, blue, and green) of LCD console panel stickers available for users to choose from, differentiating between power feed settings and speeding up troubleshooting are made easier. Plus, the LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.
Ideal for enterprise servers, network closets, and data centers, the PG series is an intelligent power distribution and management solution that supports high-density IT applications while minimizing the overall cost.
- Each PG PDU comes with 6 x IEC 60320 C19 and 24 x IEC 60320 C13 outlets in a 0U rack enclosure
- ARM Cortex-A8 processor for flexible control methods via LAN / COM / USB / environment sensor ports and enhanced monitoring via LCD console
- Advantageous hardware / network specification
– 1 Gbps and 100 Mbps Ethernet ports
– Remote Management Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus (over TCP/IP), Wi-Fi, 802.11 a/b/g/n network protocols, IPv6, and SMS
– Alerts / Alarms: receives alarms via SNMP, SMTP, SMS1, and syslog
– Scripting: JSON-RPC (Remote Procedure Call) protocol and Python scripting to control specified PDU unit (e.g. Switch On / Off) 1
– Security: 2-level account / password login access, and IP / MAC filter, TLS 1.2, SMTP / SMTPS protocols
– Authentication: LDAP, RADIUS, TACACS+ - Expandable installation
– Allows for connecting up to 64 PDU units with cascading
– Allows for PON port connection to an ATEN's KN series KVM over IP switch for centralized management of up to 16 cascaded PDUs2 - Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
- Environment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors such as ATEN EA1640 for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks
- Real-time LCD alert sends warnings to alert users of unusual power state
- An adjustable power cord is built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization
- Rotatable LCD Screen - capable of 180-degree rotation, delivering flexible in-rack installation
- Secure locking enhancement prevents power cords from becoming unplugged due to vibration or human error
- Supports ATEN’s eco DC (Energy & DCIM Management Web GUI) for monitoring power distribution, energy, and environmental data from PDUs and connected devices
Note:
1. To be included in a future firmware release.
2. To be included in a future firmware release.
Function | PG95330B | PG95330B2 | PG95330G |
Electrical | |||
Nominal Input Voltage | 208V 3PH (Delta) | 208V 3PH (Delta) | 400/230V 3PH (Star) |
Maximum Input Current | 30A Max 24A(UL de-rated) | 30A Max 24A(UL de-rated) | 32A Max |
Input Frequency | 50-60 Hz | 50-60 Hz | 50-60 Hz |
Input Connection | NEMA L21-30P | NEMA L15-30P | G Plug: IEC 60309 32A Red 3P+N+E U Plug: Clipsal 32A 56PA532-EO Angled Plug |
Input Power | 10808VA(Max), 8646VA(UL de-rated) | 10808VA(Max), 8646VA(UL de-rated) | 22170VA(Max) |
Outlet Type | (6) IEC 320 C19, (24) IEC 320 C13 | (6) IEC 320 C19, (24) IEC 320 C13 | (6) IEC 320 C19, (24) IEC 320 C13 |
Nominal Output Voltage | 208 VAC | 208 VAC | 230 VAC |
Maximum Output Current (Outlet) | C13: 15A(Max),12A(UL) C19: 20A(Max),16A(UL) | C13: 15A(Max),12A(UL) C19: 20A(Max),16A(UL) | C13:10A(Max), C19:16A(Max), |
Breakers | 3xUL489(2P)-20A | 3xUL489(2P)-20A | 6xUL489(1P)-16A |
Metering | Bank level Current, Voltage , PF and KWh Monitoring | Bank level Current, Voltage , PF and KWh Monitoring | Bank level Current, Voltage , PF and KWh Monitoring |
Outlet Switching | No | No | No |
Environment Sensor Ports | Yes | Yes | Yes |
Metering Accuracy | 1%* | 1%* | 1%* |
Physical Properties | |||
Dimensions (L x W x H) | 179.00 x 5.60 x 6.80 cm (70.47 x 2.2 x 2.68 in.) | 179.00 x 5.60 x 6.80 cm (70.47 x 2.2 x 2.68 in.) | 179.00 x 5.60 x 6.80 cm (70.47 x 2.2 x 2.68 in.) |
Weight | 8.41 kg ( 18.52 lb ) | 8.41 kg ( 18.52 lb ) | 8.41 kg ( 18.52 lb ) |
Power Cord Length | 3m | 3m | 3m |
Environmental | |||
Temperature (Operating / Storage) | 0 – 60℃ / -20 – 60℃ | 0 – 60℃ / -20 – 60℃ | 0 – 60℃ / -20 – 60℃ |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing | 0 – 80% RH, Non-Condensing | 0 – 80% RH, Non-Condensing |
Compliance | |||
EMC Verification | FCC | FCC | CE, EMC |
Safety Verification | UL, PSE | UL, PSE | CE, UL, PSE |
Warranty | 3 years | 3 years | 3 years |
Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. |
Datasheet
pg95230-95330-96230-96330-98230-98330-series-3-phase-intelligent-pdu-datasheet-en.pdf (1.38 MB)User Manual
File Name | Release Date |
pg95230-pg95330-pg96230-pg96330-pg98230-pg98330-user-manual-w.pdf (6.93 MB) | 2023-07-12 |
Quick Start Guides
3-Phase_eco_pdu_qsg.pdf (1.43 MB)CAD Drawing
pg95330b_pg95330b2-asm_V01_CAD_DRAWING.pdf (118.51 KB) pg95330g-asm_V01_CAD_DRAWING.pdf (122.08 KB)Firmware
Desc. | Ver. | Release Date | File Name |
Firmware Upgrade | v1.0.099 | 2024-01-29 | PG9-568-v1.0.099.zip |
Firmware Upgrade | v1.0.096 | 2023-12-07 | PG9-568-v1.0.096.zip |
Firmware Upgrade | v1.0.087 | 2023-01-31 | PG9-568-v1.0.087.zip |
Firmware Upgrade | v1.0.086 | 2022-12-01 | PG9_568_v1.0.086.zip |
Firmware Upgrade | v1.0.079 | 2022-10-13 | PG9_568_v1.0.079.zip |
Firmware Upgrade | v1.0.078 | 2022-09-27 | PG9_568_v1.0.078.zip |
Software & Drivers
OS | Desc. | Ver. | Release Date | File Name |
IP Installer | ||||
IP Installer | v1.4.132 | 2012-02-10 | IPInstaller-ALTUSEN_v1.4.132.zip | |
MIB File | ||||
PG MIB File | v1.1.104 | 2023-02-02 | PG_MIB_v1.1.104.zip | |
Others | ||||
Linux | PMonitor | v1.1.107 | 2013-03-08 | PMonitor_linux_v1.1.107.zip |
Windows | PMonitor | v1.0.081 | 2012-02-10 | PMonitorSrv_v1.0.081.zip |